您當(dāng)前位置:華儀通泰 > 核輻射檢測(cè)及防護(hù) » 放療質(zhì)控 » > 美國(guó)CIRS 002LFC胸部體模
  • 美國(guó)CIRS 002LFC胸部體模

美國(guó)CIRS 002LFC胸部體模

美國(guó)CIRS 002LFC胸部體模用于放療中測(cè)試胸部和肺部的胸部體模。

關(guān)鍵字:CIRS 002LFC,CIRS 002LFC胸部體模,美國(guó)CIRS胸部體模

  • 聯(lián)系電話:王經(jīng)理 13261731718
  • QQ咨詢:2881699718
產(chǎn)品詳情

美國(guó)CIRS 002LFC胸部體模用于放療中測(cè)試胸部和肺部的胸部體模。


美國(guó)CIRS 002LFC胸部體模產(chǎn)品簡(jiǎn)介:

The CIRS Model 002LFC IMRT Thorax Phantom for Film and Ion chamber Dosimetry is designed to address the complex issues surrounding commissioning and comparison of treatment planning systems while providing a simple yet reliable method for verification of individual patient plans and delivery.

The 002LFC is elliptical in shape and properly represents an average human torso in proportion, density and two-dimensional structure. It measures 30 cm long x 30 cm wide x 20 cm thick. The phantom is constructed of proprietary tissue equivalent epoxy materials. Linear attenuations of the simulated tissues are within 1% of actual attenuation for water and bone, and within 3% for lung from 50 keV to 15 MeV.

Tissue equivalent interchangeable rod inserts accommodate ionization chambers allowing for point dose measurements in multiple planes within the phantom. Hole placement allows verification in the most critical areas of the chest. One half of the phantom is divided into 12 sections, each 1 cm thick, to support radiographic or GafChromic? film. Additional inserts are available to support a variety of other detectors including TLD’s, MOSFET, and diodes.

Handling, assembly and proper orientation of the phantom is made easy with the use of a unique alignment base and holding device. The surfaces of the phantom are marked for ease of laser alignment. CT markers are included to ensure accurate film to plan registration on the center film.



美國(guó)CIRS 002LFC胸部體模產(chǎn)品特點(diǎn):

Verify heterogeneity corrections

Correlate CTU to electron density

Check dose distributions in sensitive areas

Check depth doses and absolute dose

2D and 3D isodoses

Calibrate film with ion chamber & other detectors*

Verify individual patient treatment plans

IMRT Verification System

CIRS IMRT phantoms are manufactured from tissue equivalent materials that mimic within 1% from 50 keV to 15 MeV for accurate simulation from CT planning to treatment delivery. The interchangeable rod design allows the phantom to accommodate a multitude of dose measurement devices such as ion chambers, TLD, diodes and MOSFET's in the same location within the phantom.* Phantom cross sections accommodate GafChromic? or standard ready-pack films.

*NOTE: This product or an optional accessory of this product requires a CIRS dosimetry cavity code before an order can be placed. Please refer to the Dosimetry Cavity Codes document to identify the CIRS code for the probe you intend to use with this product.

The CIRS line of IMRT phantoms is compatible with the RIT 113 software for film to plan analysis. GafChromic? is a registered trademark of International Specialty Products, Wayne, NJ.